Main Content
Generate Non-Clocked Digital Data
This example shows how to write data to two lines on an NI 6255.
Discover NI devices connected to your system and find the ID for the NI 6255.
d = daqlist("ni")
dev = 3×4 table DeviceID Description Model DeviceInfo ________ ___________________________________ __________ _______________________ "Dev1" "National Instruments(TM) USB-6255" "USB-6255" [1×1 daq.ni.DeviceInfo] "Dev2" "National Instruments(TM) USB-6363" "USB-6363" [1×1 daq.ni.DeviceInfo]
Create a DataAcquisition object and add two digital output lines from port
0
on Dev1
.
d = daq("ni"); addoutput(d,"Dev1","Port0/Line0:1","Digital"); d.Channels
ans = Index Type Device Channel Measurement Type Range Name _____ _____ ______ _____________ ________________ _____ __________________ 1 "dio" "Dev1" "port0/line0" "OutputOnly" "n/a" "Dev1_port0/line0" 2 "dio" "Dev1" "port0/line1" "OutputOnly" "n/a" "Dev1_port0/line1"
Generate digital output.
write(d,[1 0])