Main Content

FCC Peripheral Configuration

Map FCC peripherals in the model to peripheral registers in MCU

Since R2024a

Description

View and edit the map of peripherals in the Infineon® AURIX™ model to the hardware peripherals.

Using the Hardware Mapping tool, you can:

  • View and edit the configuration parameters for FCC block.

  • Check for any conflicts between the peripherals.

FCC peripheral

Open the FCC Peripheral Configuration

In the Hardware tab of the simulink model, click Hardware Mapping.

Hardware Mapping FCC

Parameters

expand all

Input

Select the input pin number.

Select this option to enable connection to the digital port to output the status of the boundary flag.

Select pin number for the digital port that outputs the boundary flag status.

Dependencies

To enable this parameter, select the Enable boundary flag output port parameter.

Input > Pin settings

Select the input mode for the FCC pin.

Select the strength of output pins.

Dependencies

To enable this parameter, select the Enable boundary flag output port parameter.

Select the speed of FCC pin.

Select the voltage level of the FCC pin.

Threshold > Threshold trigger

Specify the initial value for the threshold update.

Dependencies

To enable this parameter, set the Mode parameter to Normal or Hysteresis in the FCC block in the Simulink® model.

Set the type of trigger to Software trigger - Sample Time or Hardware trigger to update the threshold value during run time.

Dependencies

To enable this parameter, set the Mode parameter to Normal or Hysteresis in the FCC block in the Simulink model.

Select the source of the hardware trigger to update the threshold value during run time.

Dependencies

To enable this parameter, set the Threshold update on parameter to Hardware trigger.

Select hardware trigger to update the threshold value during run time.

Dependencies

This parameter appears only if you select the Threshold update on parameter as Hardware trigger.

Select the type of hardware trigger edge to update the threshold value during run time.

Dependencies

To enable this parameter, set the Threshold update on parameter to Hardware trigger.

Specify the trigger delay to update the threshold value during run time.

Dependencies

To enable this parameter, set the Threshold update on parameter to Hardware trigger.

Threshold > Hysteresis

Specify the upper delta limit for the threshold value in the hysteresis mode of operation.

Dependencies

To enable this parameter, set the Mode parameter to Hysteresis in the FCC block in the Simulink model.

Specify the lower delta limit for the threshold value in the hysteresis mode of operation.

Dependencies

To enable this parameter, set the Mode parameter to Hysteresis in the FCC block in the Simulink model.

Threshold > Ramp

Specify the initial threshold value at the start of the ramp mode of operation.

Dependencies

To enable this parameter, set the Mode parameter to Ramp in the FCC block in the Simulink model.

Specify the initial threshold value at the end of the ramp mode of operation.

Dependencies

To enable this parameter, set the Mode parameter to Ramp in the FCC block in the Simulink model.

Specify the initial step width of the ramp.

Dependencies

To enable this parameter, set the Mode parameter to Ramp in the FCC block in the Simulink model.

Specify the initial step size of the ramp.

Dependencies

To enable this parameter, set the Mode parameter to Ramp in the FCC block in the Simulink model.

Select the trigger source to start the ramp.

Dependencies

To enable this parameter, set the Mode parameter to Ramp in the FCC block in the Simulink model.

Specify the trigger or source to end of the ramp. You can select the Boundary flag transition or End of threshold value option if you set the Ramp start on parameter to Software trigger - Sample time.

Dependencies

To enable this parameter, set the Mode parameter to Ramp in the FCC block in the Simulink model.

Threshold > Trigger

Select the source of the hardware trigger.

Dependencies

To enable this parameter, set the Ramp start on parameter to Hardware trigger.

Select the hardware trigger for the threshold update in the ramp mode.

Dependencies

To enable this parameter, set the Ramp start on parameter to Hardware trigger or Ramp end on parameter as Hardware trigger or End of threshold value.

Select the type of the hardware trigger edge for the threshold update in the ramp mode.

Dependencies

To enable this parameter, set the Ramp start on parameter to Hardware trigger or the Ramp end on parameter to Hardware trigger or End of threshold value.

Specify the trigger delay for threshold update in ramp mode.

Dependencies

To enable this parameter, set the Ramp start on parameter to Hardware trigger or the Ramp end on parameter to Hardware trigger or End of threshold value.

Boundary flag

Specify the number of glitches to filter out in the input signal.

Activate boundary flag based on threshold value.

Boundary flag > Gate

Specify when to enable the boundary flag.

Specify the source of gate signal to enable the boundary flag.

Note

Ensure that you have configured the appropriate trigger from the PWM block.

Dependencies

To enable this parameter, set the Flag enable on parameter to Gate High or Gate Low.

Select hardware trigger to enable the boundary flag.

Dependencies

To enable this parameter, set the Flag enable on parameter to Gate High or Gate Low.

Select the type of hardware trigger edge to enable the boundary flag

Dependencies

To enable this parameter, set the Flag enable on parameter to Gate High or Gate Low.

Specify the gate trigger delay to enable the boundary flag.

Dependencies

To enable this parameter, set the Flag enable on parameter to Gate High or Gate Low.

Boundary flag > Boundary flag connection

Specify the number of boundary flag connections.

Boundary flag > Connection #

Specify the module for boundary flag connections.

Dependencies

To enable this parameter, set the Number of connections parameter to a value greater than 0.

Specify the channels for the PWM module selected.

Dependencies

To enable this parameter, set the Number of connections parameter to a value greater than 0.

Events > Service request - 0

Service request based on boundary flag edges.

Events > Service request - 1

Service request based on the mode of the threshold update. You can select the option End of ramp in Ramp mode and New threshold update in Normalor Hysteresis mode of operation.

Version History

Introduced in R2024a

See Also