EVADC Peripheral Configuration
Map EVADC peripherals in the Infineon AURIX model to peripheral registers in the MCU
Since R2024a
Description
View and edit the map of peripherals in the Infineon® AURIX™ model to the hardware peripherals.
Using the Peripheral Configuration tool, you can:
View and edit configuration parameters for EVADC peripheral block.
Configure the global parameters. To set the group peripheral, select peripheral in BrowserPeripherals
EVADC
. For more information, see Map Tasks and Peripherals Using Hardware Mapping.Check for any conflicts between peripherals.
Open the EVADC Peripheral Configuration
In the Hardware tab, click Hardware Mapping.
Parameters
Supply voltage
— EVADC module voltage supply
Automotive
(default) |
5V
|
3.3V
Set the voltage supply for EVADC module.
Global profile 0(0-4095)
— Global limit setting for profile 0
4095
(default) | scalar in the range (0, 4095)
Specify the global limit for profile 0.
Global profile 1(0-4095)
— Global limit setting for profile 1
0
(default) | scalar in the range (0, 4095)
Specify the global limit for profile 1.
Start-up calibration
— Option to enable group startup calibration
off
(default) |
on
Select to enable group start up calibration.
Request slot priority
— Queue priority for ADC conversion
Highest
(default) |
High
|
Low
|
Lowest
Select queue priority for ADC conversion for group #.
Request slot start mode
— Slot start mode
Cancel-Inject-Repeat
(default) |
Wait for Start
Select slot start mode for ADC conversion for group #.
Gating source
— Option to select gating source
GTM ADC trigger signal 0
(default) |
GTM ADC trigger signal #
Select source of gating for ADC conversion request for group #. For more information on EVADC trigger signals, refer to EVADC Trigger Signals.
Gating mode
— Select gating mode
Always
(default) |
High
|
Low
|
Disabled
Select gating mode for ADC conversion request for group #.
Trigger source
— Trigger source for ADC conversion
Software-Block sample time
(default) |
Software-Trigger block
|
GTM ADC trigger signal#
Select trigger source for ADC conversion for group #.
Trigger mode
— Trigger mode for ADC conversion
Disabled
(default) |
Any edge
|
Rising edge
|
Falling edge
Select trigger mode for ADC conversion.
Dependencies
To enable this parameter, set the Trigger source
parameter to GTM ADC trigger signal#
.
Group profile 0(0-4095)
— Group limit for profile 0
4095
(default) | scalar in the range [0, 4095]
Group limit setting for profile 0.
Group profile 1(0-4095)
— Group limit setting for profile 1
0
(default) | scalar in the range [0, 4095]
Group limit setting for profile 1.
Synchronize group with
— Select the controller group
None
(default) | options vary based on the group tab
Select the controller group to synchronize with G#.
Note
You cannot configure a group as peripheral, if it is already selected as the controller.
You cannot configure a group as the controller, if it is already selected as peripheral.
Select read block
— Select EVADC read block to pair with
options list all the EVADC read blocks present in the model
Select the EVADC read blocks available in the Simulink® model.
Dependencies
To enable this parameter, set the Mode parameter to
ADC trigger
in the EVADC block in the Simulink
model.
Select group
— Channel group for ADC conversion
G0
(default) | options vary based on selection of TC3xx series in configuration parameters
window
Select group for ADC conversion.
Dependencies
To enable this parameter, set the Mode parameter to
ADC read
in the EVADC block in the Simulink
model.
Select queue
— Select queue for ADC conversion
Queue 0
(default) |
Queue 1
|
Queue 2
Select queue for ADC conversion.
Dependencies
To enable this parameter, set the Mode parameter to
ADC read
in the EVADC block in the Simulink
model.
Select pins
— Select analog pin
AN0
(default) |
AN0
to AN7
Select the analog pin for ADC conversion.
Conversion type
— ADC conversion type
one-shot
(default) |
Continuous
Select conversion mode for EVADC channel group.
Use channel 0 of group as voltage reference
— Use channel 0 of the controller group as voltage reference
off
(default) |
on
Select to use channel 0 input as alternate voltage reference for channels other than channel 0 of the group.
Dependencies
To enable this parameter, set the Select group
parameter to a value other than Channel 0
in the
G# tab.
Generate parallel output for same channel numbers of synchronized group
— Generate parallel output for same channel numbers of synchronized group
off
(default) |
on
Select to generate parallel output for same channel numbers of synchronized group.
Dependencies
To enable this parameter, set the Select group parameter to the controller group, which is selected in Synchronize group with parameter in the G# tab.
Result register
— Result register for ADC channel group
Result 0
(default) | Result 1
| Result 2
| ...
Select the result register ranging between Result 0
through Result 15
for EVADC channel group.
Wait for read
— Option to enable register to wait to read result to avoid loss of data
Off
(default) |
On
Select this parameter to enable the register to wait and read the EVADC channel result registers.
Left aligned storage
— Option to enabled left-aligned storage
Off
(default) |
On
Select to enable left aligned storage of conversion result in result registers.
Data modification modes
— Selection of data modification modes
None
(default) | Standard Data Reduction (this option appears if you disable the Wait for read
parameter) |
Difference Mode
Specify data modification mode of conversion result in result registers.
Data reduction control modes
— Data reduction control mode for result register
Mode 0
(default) |
Mode 0
to Mode 15
Specify data reduction control mode for result register.
Dependencies
To enable this parameter, set the Data modification
modes parameter to Standard Data
Reduction
.
Limit checking event
— Criteria for generating limit check interrupts
Disabled
(default) |
Enabled
Select criteria for generating limit check interrupts.
Limit service request node
— Option to select limit service request node
Group Service Request Node 0
(default) |
Group Service Request Node 1
|
Group Service Request Node 2
|
Group Service Request Node 3
Select limit service request node for channel #.
Dependencies
To enable this parameter, select the Limit checking event parameter.
Result event
— Result event for channel #
Disabled
(default) |
Enabled
Result event for channel #.
Result service request node
— Select result service request node
Group Service Request Node 0
(default) |
Group Service Request Node 1
|
Group Service Request Node 2
|
Group Service Request Node 3
Select result service request node for channel #.
Dependencies
To enable this parameter, select the Result event parameter.
Boundary extension
— Boundary extension for channel #
Disabled
(default)
Select boundary extension for channel #.
Dependencies
To enable this parameter, select the Limit checking event parameter.
Limit check selection
— Limit check selection for channel #
Within Limit
(default) |
Beyond Limit
|
Within and Beyond Limit
Select limit check selection for channel #.
Dependencies
To enable this parameter, select the Limit checking event parameter.
Upper limit selection
— Upper threshold of channel #
Group profile0
(default) |
Group profile1
|
Global profile0
|
Global profile1
Select upper threshold of channel # for checking limit.
Dependencies
To enable this parameter, select the Limit checking event parameter.
Lower limit selection
— Lower threshold of channel #
Group profile1
(default) |
Group profile0
|
Global profile0
|
Global profile1
Select lower threshold of channel # for checking limit.
Dependencies
To enable this parameter, select the Limit checking event parameter.
Version History
Introduced in R2024a
MATLAB Command
You clicked a link that corresponds to this MATLAB command:
Run the command by entering it in the MATLAB Command Window. Web browsers do not support MATLAB commands.
Select a Web Site
Choose a web site to get translated content where available and see local events and offers. Based on your location, we recommend that you select: .
You can also select a web site from the following list
How to Get Best Site Performance
Select the China site (in Chinese or English) for best site performance. Other MathWorks country sites are not optimized for visits from your location.
Americas
- América Latina (Español)
- Canada (English)
- United States (English)
Europe
- Belgium (English)
- Denmark (English)
- Deutschland (Deutsch)
- España (Español)
- Finland (English)
- France (Français)
- Ireland (English)
- Italia (Italiano)
- Luxembourg (English)
- Netherlands (English)
- Norway (English)
- Österreich (Deutsch)
- Portugal (English)
- Sweden (English)
- Switzerland
- United Kingdom (English)
Asia Pacific
- Australia (English)
- India (English)
- New Zealand (English)
- 中国
- 日本Japanese (日本語)
- 한국Korean (한국어)