Integrate Externally Defined Identifiers
The coder allows you to suppress identifier (symbol) definitions in the generated code. This suppression allows you to integrate a custom element, such as user-defined function blocks, function blocks, data types, and named global variable and constants, in place of one generated from a Simulink® subsystem. You must then provide these definitions when importing the code into the target IDE. You must:
Define the custom element in the subsystem for which you want to generate code.
Name the custom element.
In the Configuration Parameters dialog box, add the name of the custom element to PLC Code Generation > Identifiers > Externally Defined Identifiers in the Configuration Parameters dialog box.
Generate code.
For a description of how to integrate a custom function block, see Integrate Custom Function Block in Generated Code. For a description of the Externally Defined Identifiers parameter, see Externally Defined Identifiers.