主要内容

Battery (System-Level)

R2026b

Generic system level battery

Since R2022a

Libraries:
Simscape / Driveline / Sources

Description

The Battery (System-Level) block represents a generic self-discharging battery. You can use the block to model hybrid and battery electric drives at a medium-level fidelity for drive cycle analysis. The block is a simplified version of the Battery (Simscape Electrical) block and uses the same parameters, where applicable. This will aid your transition to a higher fidelity model, if necessary. The Battery (System-Level) does not support battery fade, aging, dynamics, or temperature dependent properties. You can access these features using the Battery (Simscape Electrical) block.

You can choose to simulate a battery with finite or infinite charge. The block can also help you to determine how decreased voltage affects performance and control requirements. To learn more about observing battery performance, see Plot Basic Voltage-Charge Characteristics of Battery Blocks (Simscape Electrical).

Battery Model

When you set Battery charge capacity to Infinite, the block treats the battery like a resistor and a constant voltage source in series. When you set Battery charge capacity to Finite, the block treats the battery like a resistor and a charge-dependent voltage source in series. In this case, the voltage is a function of charge and has the following relationship:

V=V0SOC1β(1SOC)

where:

  • SOC (state-of-charge) is the ratio of current charge to rated battery capacity.

  • V0 is the voltage when the battery is fully charged at no load, as defined by the Nominal voltage, Vnom parameter.

  • β is a constant that is calculated so that the battery voltage is V1 when the charge is AH1. Specify the voltage V1 and ampere-hour rating AH1 using block parameters. AH1 is the charge when the no-load (open-circuit) voltage is V1, and V1 is less than the nominal voltage.

The equation defines an approximate relationship between voltage and remaining charge. This approximation replicates the increasing rate of voltage drop at low charge values and ensures that the battery voltage becomes zero when the charge level is zero. The advantage of this model is that it requires few parameters, which are typically available on manufacturer datasheets.

Variables

To set the priority and initial target values for the block variables prior to simulation, use the Initial Targets section in the block dialog box or Property Inspector. For more information, see Set Priority and Initial Target for Block Variables.

Nominal values provide a way to specify the expected magnitude of a variable in a model. Using system scaling based on nominal values increases the simulation robustness. Nominal values can come from different sources, one of which is the Nominal Values section in the block dialog box or Property Inspector. For more information, see Modify Nominal Values for a Block Variable.

Assumptions and Limitations

The block assumes that self-discharge resistance does not depend on the number of discharge cycles.

Ports

Conserving

expand all

Electrical conserving port associated with the positive battery terminal.

Programmatic Use

Port: p

Electrical conserving port associated with the negative battery terminal.

Programmatic Use

Port: n

Thermal conserving port associated with heat transfer.

Dependencies

To expose this port, set Thermal port to Model.

Programmatic Use

Port: H

Parameters

expand all

Main

No-load voltage across the battery when it is fully charged.

Programmatic Use

Parameter: Vnom

Internal connection resistance of the battery.

Programmatic Use

Parameter: R1

Option to simulate finite or infinite battery charge capacity.

Programmatic Use

Parameter: prm_AH
Values: "sdl.enum.InfiniteFinite.Infinite" | "sdl.enum.InfiniteFinite.Finite"

Maximum battery charge. Ampere-hours refer to the number of hours that the battery can discharge 1 Amp. You can specify an initial charge target as a variable.

Dependencies

To enable this parameter, set Battery charge capacity to Finite.

Programmatic Use

Parameter: AH

Fundamental battery output voltage when the charge level is equal to the Charge AH1 when no-load voltage is V1.

Dependencies

To enable this parameter, set Battery charge capacity to Finite.

Programmatic Use

Parameter: V1

Battery charge level corresponding to the no-load output voltage you specify for the Voltage V1 when charge is AH1 parameter.

Dependencies

To enable this parameter, set Battery charge capacity to Finite.

Programmatic Use

Parameter: AH1

Option to simulate self-discharge resistance. The block simulates this effect as a resistor across the terminals of the battery.

Dependencies

To enable this parameter, set Battery charge capacity to Finite.

Programmatic Use

Parameter: prm_R2
Values: "sdl.enum.DisabledEnabled.Disabled" | "sdl.enum.DisabledEnabled.Enabled"

Resistance across the battery terminals that represents self-discharge.

Dependencies

To enable this parameter, set Battery charge capacity to Finite and Self-discharge to Enabled.

Programmatic Use

Parameter: R2

Thermal Port

Option to expose the thermal port and include thermal effects in your model.

Programmatic Use

Parameter: thermal_port
Values: "simscape.enum.thermaleffects.omit" | "simscape.enum.thermaleffects.model"

Thermal energy required to change the component temperature by a single degree. The greater the thermal mass, the more resistant the component is to temperature change.

Programmatic Use

Parameter: thermal_mass

Extended Capabilities

expand all

C/C++ Code Generation
Generate C and C++ code using Simulink® Coder™.

Version History

Introduced in R2022a

See Also