Wye-Connected Variable Load
R2026bThree-phase variable load wired in wye configuration
Libraries:
Simscape /
Electrical /
Passive /
RLC Assemblies
Description
The Wye-Connected Variable Load block models a three-phase variable load wired in a wye configuration. Each limb of the load contains a resistor. The block calculates the resistance required to draw the real power of the physical signal input P at the rated voltage that you specify. Therefore, the block can represent a real load.
To ensure that the resistance is always greater than zero, you specify the minimum real power that the load consumes. The minimum real power must be greater than zero.
Equations
This equation defines the resistance,
where:
R is the per-phase series resistance.
VRated is the RMS, rated line-line voltage.
P is the three-phase real power required.
Ports
Input
Conserving
Parameters
Programmatic Use: Add Block
To add the block programmatically, use the add_block function with one of these library block paths as the source.
"ee_lib/Passive/RLC Assemblies/Wye-Connected Variable Load"
Example: add_block("ee_lib/Passive/RLC Assemblies/Wye-Connected Variable Load","myModel/myBlock",MakeNameUnique="on")
For information about programmatic access to individual block parameters, see the Programmatic Use section of parameter descriptions on this page.