hisl_0303: Configuration Parameters > Diagnostics > Data Validity > Merge blocks
R2026bSet Merge block driving blocks diagnostic to error to improve design robustness
Usage: High-Integrity System Modeling
Guideline ID: hisl_0303
Rules
| hisl_0303: Configuration Parameters > Diagnostics > Data Validity > Merge blocks |
|---|
Set configuration parameter
Detect multiple driving blocks executing at the same time
step to Rationale Improve robustness of design. Verification Check safety-related diagnostic settings for Merge blocks (Simulink Check) |
Industry Standards
DO-331 MB.6.3.2 (b) Accuracy and Consistency
IEC 61508-3, Table A.3 (3) - Language subset
IEC 62304, 5.5.3 - Software Unit acceptance criteria
ISO 26262-6, Table 1 (1b) - Use of language subsets
EN 50128, Table A.4 (11) - Language Subset
EN 50657, Table A.4 (11) - Language Subset