Main Content
jc_0061: Display of block names
Since R2020a
Guideline Publication
Control Algorithm Modeling Guidelines - Using MATLAB®, Simulink®, and Stateflow®
Sub ID Recommendations
NA-MAAB — a
JMAAB — a
MATLAB Versions
All
Rule
Sub ID a
Block names shall be hidden for blocks that meet either of these criteria:
Block type is evident from its visual appearance
Uses the default block name (including instances where only a number has been added at the end)
For blocks that do not meet the criteria, their name shall be displayed.
Custom Parameter
Blocks with a clear type due their appearance
Example — Displayed block names
Example — Hidden block names
Rationale
Sub ID a:
Improves model readability.
Verification
Model Advisor check: Check the display attributes of block names (Simulink Check)
Last Changed
R2020a
See Also
MISRA AC SLSF 026A
Version History
Introduced in R2020a