Sub ID Recommendations

  • NA-MAAB — No recommendations

  • JMAAB — a

MATLAB Versions

All

Rule

Sub ID a

Block parameters that are targets of calibration shall be defined as named constants. Examples of parameters that are outside of the calibration target include:

  • Initial value parameter 0

  • Increment, decrement 1

  • Arithmetic expressions

Custom Parameter

Not Applicable

Example — Correct

Example — Incorrect

Rationale

Sub ID a:

  • A literal constant in the model will propagate as a literal constant in the generated code, making calibration impossible.

Verification

Model Advisor check: Check if tunable block parameters are defined as named constants (Simulink Check)