jc_0770: Position of transition label
Since R2020a
Guideline Publication
Control Algorithm Modeling Guidelines - Using MATLAB®, Simulink®, and Stateflow®
Sub ID Recommendations
NA-MAAB — No recommendations
JMAAB — a1/a2
MATLAB Versions
All
Rule
Sub ID a1
Transition labels are positioned at the transition line point of origin.
Not Applicable
Transition labels are positioned at the point of origin.
The positioning of transition labels is inconsistent and do not correspond to the transition line.
Sub ID a2
Transition labels are positioned near the center of the transition line.
Not Applicable
Transition labels are positioned near the center of the transition line.
The positioning of transition labels is inconsistent and do not correspond to the transition line.
Rationale
Sub IDs a1, a2:
Consistent positioning of transition labels makes the correspondence between label and line easier to understand.
Verification
Model Advisor check: Check placement of Label String in Transitions (Simulink Check)
Last Changed
R2020a
See Also
Transition Between Operating Modes (Stateflow)
Version History
Introduced in R2020a