Check safety-related diagnostic settings for Merge blocks
Check ID:
mathworks.hism.hisl_0303
Check model configuration for diagnostic settings that apply to Merge blocks
Description
This check verifies that model configuration parameters are set optimally for Merge blocks for a safety-related application.
Available with Simulink® Check™.
Results and Recommended Actions
Condition | Recommended Action |
---|---|
The diagnostic that detects whether a model contains Merge blocks
with more than one driving block executing at the same time step is set
to none or
warning . | In the Configuration Parameters dialog box, set Detect multiple driving blocks executing at the same time step or set the parameter
|
Action Results
Clicking Modify Settings configures model diagnostic settings that apply to solvers and that can impact safety.
Capabilities and Limitations
Does not run on library models.
Does not allow exclusions of blocks or charts.
See Also