Real-Time Controller
This example shows how to build a simple closed-loop real-time controller by using Simulink® Desktop Real-Time™. The output of the controlled plant is connected to the analog input of your data acquisition board. This signal is subtracted from the set point value generated by the signal generator and processed by a PID controller. The output of the controller drives the input of the plant by using the analog output of your data acquisition board.
This model is a simplified version of the controller used for the http://www.humusoft.cz/produkty/models/ce152
CE152 Magnetic Levitation Model.
Note: To run this model, you must have a data acquisition board connected to your computer.
Run Model in Connected IO Mode
Open the Analog Input and Analog Output blocks and select your data acquisition board. If there is no board installed, install it by clicking the Install new board button.
To switch to Connected IO mode if needed, on the Desktop Real-Time tab, select Mode > Connected IO.
To start the real-time execution, click Run in Real-Time.
Run Model in Run in Kernel Mode
Open the Analog Input and Analog Output blocks and select your data acquisition board. If there is no board installed, install it by clicking the Install new board button.
To switch to Run in Kernel mode if needed, on the Desktop Real-Time tab, select Mode > Run in Kernel.
To start the real-time execution, click Run in Real Time.
The model builds, connects to Simulink in Run in Kernel mode, and starts.
Open the Model
open_system('sldrtex_controller');
Close Open Scopes
close_system(find_system(gcs ,'BlockType', 'Scope'));
Clean Up Model
clear close all bdclose all