Multimeter
Measure voltages and currents specified in dialog boxes of Simscape Electrical Specialized Power Systems blocks
Libraries:
Simscape /
Electrical /
Specialized Power Systems /
Sensors and Measurements
Description
This block measures the voltages and currents specified in the Measurements parameter of Simscape™ Electrical™ Specialized Power Systems blocks in your model. Choosing voltages or currents through the Multimeter block is equivalent to connecting an internal voltage or current measurement block inside your blocks.
Polarity of Measured Voltages and Currents
The polarity of the measured voltages and current is determined by the + and - terminals of the measured Simscape Electrical Specialized Power Systems blocks. The following table identifies the positive terminals of the Simscape Electrical Specialized Power Systems blocks that do not have the + sign to identify block polarity.
Block | Positive terminal(s) |
---|---|
1 2 3 ABC | |
ABC ABC | |
ABC | |
1 |
For three-phase transformers, the voltage polarities and positive current directions are indicated by the signal labels used in the Multimeter block. For example, Uan_w2 = phase A-to-neutral voltage of the Y connected winding #2 and Iab_w1 = winding current flowing from A to B in the delta-connected winding #1.
The Multimeter block is not designed to be used in a model that contains more than one powergui block.
Examples
The power_compensated
example uses a Multimeter block
to measure the voltage across the secondary winding of a Saturable
Transformer block and the currents flowing through two Series RLC
Load blocks.
The output of the Multimeter block is connected to a Scope block in order to display the measurements during the simulation. In addition, you can select the Plot Output Measurements at simulation stop parameter to display a plot of selected measurements when simulation stops.
Open the Multimeter block dialog box and select the signals you want to observe, as described in the Parameters section. Notice the labels used to define the available measurements in the Multimeter block. For a description of these labels, see the reference section of the Saturable Transformer block and Series RLC Load block.
Start the simulation. After 0.4 seconds, the simulation stops and a MATLAB® figure window opens to display the selected measurements in the Multimeter block.
Parameters
Extended Capabilities
Version History
Introduced before R2006a