Power
Compute active and reactive powers of voltage-current pair at fundamental frequency
Libraries:
Simscape /
Electrical /
Specialized Power Systems /
Sensors and Measurements
Description
The Power block computes the active power (P), in watts, and the reactive power (Q), in vars, of a voltage-current pair at fundamental frequency. To perform this computation, the block first determines the fundamental values (magnitude and phase) of the two input signals V & I. The following P and Q are then calculated:
As this block uses a running average window, one cycle of simulation must complete before the outputs give the correct value. For the first cycle of simulation, the outputs are held constant using the values specified by the Voltage initial input and Current initial input parameters.
Examples
The power_Power
model shows the accuracy of the Power block in
evaluating the active and reactive powers of a voltage-current set.
The model sample time is parameterized by the Ts variable set to a default value of 50e-6 s. Set Ts to 0 in the command window to simulate the model in continuous mode.
Characteristics
Sample Time | Specified in the Sample Time
parameter Continuous if Sample Time = 0 |
Scalar Expansion | Yes, of the parameters |
Dimensionalized | Yes |
Ports
Input
Output
Parameters
Extended Capabilities
Version History
Introduced in R2013a