Power (3ph, Phasor)
Compute three-phase active and reactive powers using three-phase voltage and current phasors
Library
Simscape / Electrical / Specialized Power Systems / Sensors and Measurements
Description
The Power (3ph, Phasor) block outputs total active power P and reactive power Q of a three-phase voltage-current phasor signal pair. P and Q are computed as follows:
Ia*, Ib*, Ic* are the complex conjugates of Ia, Ib, and Ic.
The figure shows sign conventions:

Inputs and Outputs
VabcThe three-phase phasor (three complex signals) voltage signal, in volts peak.
IabcThe three-phase phasor (three complex signals) current signal, in amperes peak.
PReturns the total active power, in watts.
QReturns the total active power, in vars.
Characteristics
| Direct Feedthrough | Yes |
| Dimensionalized | No |
Examples
The power_PhasorPowerMeasurements example shows the use of the Power (3ph,
Phasor) block.
Version History
Introduced in R2013a