power_init
Set initial state values of model built with Simscape Electrical Specialized Power Systems software
Syntax
[x0,states] = power_init(sys)
power_init(sys,'states')
power_init(sys,'ForceToZero')
power_init(sys,'ResetToDefault')
power_init(sys,'x0')
power_init(sys,'look')
power_init(sys,'reset')
power_init(sys,'steady')
Description
Power_init
deals with two types of state variables: the Simulink® State variables and the Electrical State variables. The Simulink States consists of the entire set of state variables of a model (including
the Electrical states) seen by Simulink software. The Electrical States are the particular Simulink states that defines the capacitor initial voltages and inductor initial
currents of the Simscape™
Electrical™ Specialized Power Systems blocks of your model.
[x0,states] = power_init(sys)
returns the
initial states values and state names of your model.
power_init(sys,'states')
displays in a two-column format the initial
state values and names of your model.
power_init(sys,'ForceToZero')
sets to zero the initial states your model.
It uses the Data import/export initial state option
from the Simulation > Model Configuration Parameters
menu in the Simulink Editor to specify the initial state values. Use the
ResetToDefault
option of
power_init
to reset the Simulink configuration parameters to its previous settings.
power_init(sys,'ResetToDefault')
resets the initial state of Simulink configuration parameters to the settings prior to the use of the ForceToZero
option of power_init
. This
option has no effect on system if the ForceToZero
option
is not used before.
power_init(sys,'x0')
sets the initial state values equal to the vector
specified by x0. The ordering of the states variables is given by the state
option of power_init
. This option
uses the Data import/export initial state option from
the Simulation > Model Configuration Parameters menu
in the Simulink Editor to specify the initial state values.
power_init(sys,'look')
displays
in a two-column format the electrical initial states names and values
of your model.
power_init(sys,'reset')
resets
the electrical initial states of sys to zero.
power_init(sys,'steady')
sets
the electrical initial states of sys to simulate the electrical circuit
in the steady state.