The Programmable Voltage Source (Three-Phase) block models a three-phase voltage source with programmable AC magnitude, frequency, and phase shift. Choose the external mode to specify these quantities by physical input signals M, F, and Phi. You can add harmonics and internal impedance to the voltage source.
For relevant equations, see the Voltage Source (Three-Phase) block.
Variables
To set the priority and initial target values for the block variables before simulation, use the Initial Targets section in the block dialog box or Property Inspector. For more information, see Set Priority and Initial Target for Block Variables.
Nominal values provide a way to specify the expected magnitude of a variable in a model. Using system scaling based on nominal values increases the simulation robustness. You can specify nominal values using different sources, including the Nominal Values section in the block dialog box or Property Inspector. For more information, see System Scaling by Nominal Values.
Ports
Input
F — Frequency
physical signal
Physical signal input associated with the frequency.
M — Magnitude
physical signal
Physical signal input associated with the magnitude.
Phi — Phase shift
physical signal
Physical signal input associated with the phase shift.
Conserving
n — Neutral
electrical
Electrical conserving port associated with a neutral point.
~ — Three-phase AC voltage
electrical
Expandable electrical conserving three-phase port associated with the AC voltage.
Parameters
Modeling option — Whether to model composite or expanded three-phase ports
Composite three-phase ports
(default) | Expanded three-phase ports
Whether to model composite or expanded three-phase ports.
Composite three-phase ports represent three individual electrical conserving ports with a single block port. You can use composite three-phase ports to build models that correspond to single-line diagrams of three-phase electrical systems.
Expanded three-phase ports represent the individual phases of a three-phase system using three separate electrical conserving ports.
AC Magnitude
AC magnitude configuration — AC voltage magnitude configuration
Constant
(default) | Ramp
| Step
|
Modulation
|
External
Configure the magnitude of the AC component of the voltage.
Dependencies
Selecting Constant
,
Ramp
,
Step
, or
Modulation
exposes related
parameters.
Selecting External
exposes a physical
signal input port.
Rated voltage (phase-to-phase RMS) — Rated AC voltage
100
V
(default)
Rated AC voltage (phase-to-phase RMS).
Dependencies
To enable this parameter, set AC magnitude configuration to
Constant
,
Ramp
,
Step
, or
Modulation
.
Rate of change — AC voltage rate of change
1
V/s (default)
AC voltage rate of change.
Dependencies
To enable this parameter, set AC magnitude configuration to
Ramp
.
Step amplitude — AC voltage step amplitude
1
V (default)
AC voltage step amplitude.
Dependencies
To enable this parameter, set AC magnitude configuration to
Step
.
Modulation magnitude — AC voltage modulation magnitude
1
V
(default)
AC voltage modulation magnitude.
Dependencies
To enable this parameter, set AC magnitude
configuration to
Modulation
.
Modulation frequency — AC voltage modulation frequency
1
Hz
(default)
AC voltage modulation frequency.
Dependencies
To enable this parameter, set AC magnitude
configuration to
Modulation
.
Start time — AC voltage start time
1
s
(default)
Simulation time for start of AC voltage.
Dependencies
To enable this parameter, set AC magnitude configuration to
Ramp
,
Step
, or
Modulation
.
Stop time — AC voltage stop time
2
s
(default)
Simulation time for stop of AC voltage.
Dependencies
To enable this parameter, set AC magnitude
configuration to Ramp
,
Step
, or
Modulation
.
Frequency
AC frequency configuration — AC frequency configuration
Constant
(default) | Ramp
| Step
|
Modulation
|
External
Configure the frequency of the AC component of the voltage.
Dependencies
Selecting Constant
,
Ramp
,
Step
, or
Modulation
exposes related
parameters.
Selecting External
exposes a physical
signal input port.
Rated frequency — Rated frequency
60
Hz
(default)
Rated frequency.
Dependencies
To enable this parameter, set AC frequency configuration to
Constant
,
Ramp
,
Step
, or
Modulation
.
Rate of change — AC frequency rate of change
1
Hz/s
(default)
AC frequency rate of change.
Dependencies
To enable this parameter, set AC frequency configuration to
Ramp
.
Step amplitude — AC frequency step amplitude
1
Hz
(default)
AC frequency step amplitude.
Dependencies
To enable this parameter, set AC frequency
configuration to
Step
.
Modulation magnitude — AC frequency modulation magnitude
1
Hz
(default)
AC frequency modulation magnitude.
Dependencies
To enable this parameter, set AC frequency
configuration to
Modulation
.
Modulation frequency — AC frequency modulation frequency
1
Hz
(default)
AC frequency modulation frequency.
Dependencies
To enable this parameter, set AC frequency
configuration to
Modulation
.
Start time — AC frequency start time
1
s
(default)
Simulation time for starting AC frequency.
Dependencies
To enable this parameter, set AC frequency configuration to
Ramp
,
Step
, or
Modulation
.
Stop time — AC frequency start time
2
s
(default)
Simulation time for stopping AC frequency.
Dependencies
To enable this parameter, set AC frequency
configuration to Ramp
,
Step
, or
Modulation
.
Phase
AC phase shift configuration — AC phase shift configuration
Constant
(default) | Ramp
| Step
|
Modulation
|
External
Configure the phase of the AC component of the voltage.
Dependencies
Selecting Constant
,
Ramp
,
Step
, or
Modulation
exposes related
parameters.
Selecting External
exposes a physical
signal input port.
Phase shift — AC voltage phase shift
0
deg
(default)
AC voltage phase shift.
Dependencies
To enable this parameter, set AC phase shift configuration to
Constant
,
Ramp
,
Step
, or
Modulation
.
Rate of change — AC phase shift rate of change
1
deg/s
(default)
AC phase shift rate of change.
Dependencies
To enable this parameter, set AC phase shift configuration to
Ramp
.
Step amplitude — AC phase shift step amplitude
1
deg
(default)
AC phase shift step amplitude.
Dependencies
To enable this parameter, set AC phase shift
configuration to
Step
.
Modulation magnitude — AC phase shift modulation magnitude
1
deg
(default)
AC phase shift modulation magnitude.
Dependencies
To enable this parameter, set AC phase shift
configuration to
Modulation
.
Modulation frequency — AC phase shift modulation frequency
1
Hz
(default)
AC phase shift modulation frequency.
Dependencies
To enable this parameter, set AC phase shift
configuration to
Modulation
.
Start time — AC phase shift start time
1
s
(default)
Simulation time for starting AC phase shift.
Dependencies
To enable this parameter, set AC phase shift configuration to
Ramp
,
Step
, or
Modulation
.
Stop time — AC phase shift start time
2
s
(default)
Simulation time for stopping AC phase shift.
Dependencies
To enable this parameter, set AC phase shift configuration to
Ramp
,
Step
, or
Modulation
.
Impedance
Source impedance — Source impedance configuration
None
(default) | X/R Ratio
| Series
R
| Series L
|
Series RL
Source impedance configuration.
Dependencies
Selecting X/R Ratio
,
Series R
, Series
L
, or Series RL
exposes
related parameters.
Short-circuit power level — Short-circuit power level
1e6
V*A
(default)
Short-circuit power level.
Dependencies
To enable this parameter, set Source impedance to X/R
Ratio
.
Source X/R ratio — X/R ratio
15
(default)
Source X/R ratio.
Dependencies
To enable this parameter, set Source
impedance to X/R
Ratio
.
Source resistance — Resistance
0.01
Ohm
(default)
Source resistance.
Dependencies
To enable this parameter, set Source impedance to
Series R
or Series
RL
.
Source inductance — Inductance
3.97e-4
H
(default)
Source inductance.
Dependencies
To enable this parameter, set Source impedance to
Series L
or Series
RL
.
Parasitic parallel conductance — Parasitic parallel conductance
1e-6
1/Ohm
(default)
Parasitic parallel conductance.
Dependencies
To enable this parameter, set Source
impedance to X/R Ratio
,
Series L
, or Series
RL
.
Harmonics
Source harmonics — Source harmonics configuration
None
(default) | Generate harmonics
Configuration for the source harmonics.
Dependencies
Selecting Generate harmonics
exposes
related parameters.
Harmonic orders — Harmonic orders
[5, 7, 11, 13]
(default)
Harmonic orders.
Dependencies
To enable this parameter, set Source harmonics to
Generate harmonics
.
Harmonic to base magnitude ratios — Harmonic to base magnitude ratios
[.1, .1, .1, .1]
(default)
Harmonic to base magnitude ratios. Specify the same number of elements as is specified for the Harmonic orders parameter.
Dependencies
To enable this parameter, set Source
harmonics to Generate
harmonics
.
Harmonic phase shifts — Harmonic phase shifts
[0, 0, 0, 0]
deg
(default)
Harmonic phase shifts. Specify the same number of elements as is specified for the Harmonic orders parameter.
Dependencies
To enable this parameter, set Source
harmonics to Generate
harmonics
.
Harmonic sequences — Harmonic sequences
[1, 1, 1, 1]
(default)
Harmonic sequences:
0
indicates zero-sequence1
indicates positive-sequence2
indicates negative-sequence
Specify the same number of elements as is specified for the Harmonic orders parameter.
Dependencies
To enable this parameter, set Source
harmonics to Generate
harmonics
.
Start time — Source harmonics start time
-inf
s
(default)
Simulation time for start of source harmonics.
Dependencies
To enable this parameter, set Source
harmonics to Generate
harmonics
.
Stop time — Source harmonics stop time
inf
s
(default)
Simulation time for stop of source harmonics.
Dependencies
To enable this parameter, set Source
harmonics to Generate
harmonics
.
Extended Capabilities
C/C++ Code Generation
Generate C and C++ code using Simulink® Coder™.
Version History
Introduced in R2019a
MATLAB Command
You clicked a link that corresponds to this MATLAB command:
Run the command by entering it in the MATLAB Command Window. Web browsers do not support MATLAB commands.
Select a Web Site
Choose a web site to get translated content where available and see local events and offers. Based on your location, we recommend that you select: .
You can also select a web site from the following list
How to Get Best Site Performance
Select the China site (in Chinese or English) for best site performance. Other MathWorks country sites are not optimized for visits from your location.
Americas
- América Latina (Español)
- Canada (English)
- United States (English)
Europe
- Belgium (English)
- Denmark (English)
- Deutschland (Deutsch)
- España (Español)
- Finland (English)
- France (Français)
- Ireland (English)
- Italia (Italiano)
- Luxembourg (English)
- Netherlands (English)
- Norway (English)
- Österreich (Deutsch)
- Portugal (English)
- Sweden (English)
- Switzerland
- United Kingdom (English)
Asia Pacific
- Australia (English)
- India (English)
- New Zealand (English)
- 中国
- 日本Japanese (日本語)
- 한국Korean (한국어)