- Verify that the FMU simulates without any errors or issues in the third-party that was used to create it.
- In the FMU block, select the Enable FMU Debug Logging checkbox in the 'Simulation' tab to see a more descriptive error.

- The following “Advanced” diagnostic parameter prevents a MATLAB crash (“out-of-process mode”) in some cases:

- Use the FMU Compliance checker. This tool can help determine if the issue stems from the generated FMU not adhering to standards (i.e. an issue from a third-party tool) or with MathWorks tools. https://github.com/modelica-tools/FMUComplianceChecker/releases
- Check that the “Communication step size” is compatible with the model: https://www.mathworks.com/help/simulink/ug/implement-an-fmi-block.html#mw_f1a9abe7-d7ed-4696-8c46-42c72d74ba83
How do I troubleshoot FMU Import issues in Simulink?
25 次查看(过去 30 天)
显示 更早的评论
MathWorks Support Team
2022-11-14
编辑: MathWorks Support Team
2023-6-6
I am using an FMU block to import a third-party functionality into Simulink. I run into errors or MATLAB crashes during the import workflow. How can I debug FMU import issues in Simulink?
采纳的回答
MathWorks Support Team
2023-6-6
Imported FMUs in Simulink can cause failures for different reasons. Here are some common troubleshooting tips that will help in the debug process: