已回答
coder.extrinsic error
Hi Abhishek, In R2011b, I recommend creating a MATLAB Function block inside the chart, moving any "coder" calls inside it, an...

7 years 前 | 0

已回答
How can I use an existing Level-2 C S-Function in embedded application?
Hi Richard, Simulink Coder Code Generation using a model with a Level-2 C S-Function is a supported workflow. You should be a...

7 years 前 | 0

已回答
How to link Git remote repository to Simulink Project
Hi Christopher, To create a Simulink Project with Git inside the main project folder, try the following steps: # Open MATL...

7 years 前 | 0

已回答
Inserting #ifdef in generated code
Hi Mayuresh, The easiest way to automatically generate preprocessor conditionals is to use a variant subsystem, which is acti...

7 years 前 | 0

已回答
When I run verification with Polyspace R2012b, there is an error like this: "No code found for the system xxxx. Before running the verification, generate code using TargetLink"
Hi Augus, It is possible to receive this error if the code has only been generated for one subsystem, and not the entire mode...

7 years 前 | 0

已回答
How to include libraries for sfunction?
Hi Mario, The easiest way to include custom libraries in C S-Functions is to use the S-Function Builder block, which is locat...

7 years 前 | 0

已回答
Embedded Coder Error: Number of fields in structure arrays being concatenated do not match. Concatenation of structure arrays requires that these arrays have the same set of fields.
Hi Bryan, This error is a bug in Embedded Coder R2017a that occurs when the "Show code metrics" option listed in Configuratio...

7 years 前 | 0