已回答
change the value of a data structure field
s(3).Val='1'; s.Val [s.Val]=deal('2') s.Val

13 days 前 | 0

| 已接受

已回答
Global variables in simulink - embedded coder
I think you can try this block. Put it inside the Subsystem and specify the sample time as -1, which inherits the interrupt. ht...

13 days 前 | 0

已回答
Is there a way to change my simulink parameters at a pre-set time during the simulation?
There are ways but you are looking for "an easy way". Typically I would implement this in the model using the Step block. For e...

13 days 前 | 1

| 已接受

已回答
How to determine sets with only unique values across the columns of a large logical array?
Since it is comparing just two columns,I think you have to use loop. Utilize the logical(),all() and any() function. matrix =[0...

14 days 前 | 0

| 已接受

已回答
problem with matlab function in simulink (inpunt problem)
From the diagram, "Tt" and "Pt" are the 1st and 2nd input From the function code, "Tt" and "Pr" are the 1st and 2nd input, whil...

14 days 前 | 0

已回答
How to convert custom simulink blocks (with inports and outports created for accessing hardware interfaces) inside a subsystem into non-virtual blocks?
Select the Subsystem block, right click, select "Block Parameters (Subsystem)", check "Treat as atomic unit". This is one of th...

16 days 前 | 0

已回答
Programmatic setting of Argument attribute for parameter in Simulink model workspace
set_param('ModelName','ParameterArgumentNames','a,b,g') where a,b,g are the name of the variables. See also https://www.mathwor...

16 days 前 | 0

已回答
how to access internet web browser
Run this in MATLAB Command Window web('mathworks.com')

17 days 前 | 1

已回答
How Do I send a variable sized array from simulink to matlab workspace (using continuous time and without altering the sample time) ?
See the "Variable-size signal" example model. https://www.mathworks.com/help/releases/R2021b/simulink/slref/toworkspace.html

17 days 前 | 0

已回答
How to select variant within a model reference?
Combine this with model parameter for the model reference? https://www.mathworks.com/help/simulink/ug/mask-a-variant-subsystem....

17 days 前 | 0

已回答
How to read To Workspace block signal value to App Designer ?
Likely it is caused by this Signal1 = get_param('mymodel.slx/To Workspace1','VariableName') gives you a char array containing t...

22 days 前 | 0

| 已接受

已回答
Stateflow while-logic dead loop
When input==1, you do have an infinite loop, right? Connecting the feedback transition to the bottom junction would resolve it....

22 days 前 | 0

| 已接受

已回答
issues about zero_crossing_types.h during code generate
un-check the "Enable zero-crossing detection for fixed-step simulation" option in the Solver setting? Also, search for "zero-cr...

22 days 前 | 0

| 已接受

已回答
How to connect Inport Inport or Outport Outport programmatically
Yes. You can! I have done that using the add_line('connect_model','Constant/1','Gain/1') syntax by matching name. You are con...

22 days 前 | 0

已回答
what is that blue block in Matlab is that a subsystem? what is the actual name of that block in Matlab?
It is called an "Area". On the left side of your Simulink canvas, click that "square" icon, below the "Image" icon.

22 days 前 | 0

已回答
Signal name must resolve to Simulink signal object error
uncheck the 'Signal name must resolve to Simulink signal object' for the signal SC_*** the error goes away, like you did. Set S...

23 days 前 | 0

| 已接受

已回答
Why is microservice able to load 'txt' files from subdirectory but not ".mat" files?
Notice the two backslashes "\\" in the error message about the file? "error":{"id":"MATLAB:load:couldNotReadFile","message":"Un...

23 days 前 | 1

| 已接受

已回答
Simulink Line connection error
You might need this "Ground" block. https://www.mathworks.com/help/simulink/slref/ground.html Not the "Ground" block from SimS...

23 days 前 | 0

| 已接受

已回答
Add column in specific number range to available table
try this A.B(:,1) = randi([400,2970],[1650 1]) understand this. Generate a 3x1 matrix with random interger value that is betwe...

24 days 前 | 0

已回答
How to apply App Designer output to Constant of simulink model ?
The workspace value is compiled/built for simulaiton only once when the model is initialized. It will not be updated to the mode...

24 days 前 | 0

| 已接受

已回答
Deal with Closed MATLAB Executable and Windows command line
Based on the error message, it seems that "input1" is passed to the app when you run it in command line my_app_name input1 inpu...

24 days 前 | 0

已回答
sinusoidal elevation wave with time
Maybe this example gives you an idea? t=0:0.01:20; f1=1; y1=sin(2*pi*f1*t); f2=0.05; y2=sin(2*pi*f2*t); y0=y1.*y2; figure...

25 days 前 | 0

已回答
How can I put an output from the display function in a table?
Create a table, fill the data and display it. doc table

25 days 前 | 0

已回答
How to use integer or other datatype condition in if Block, Simulink?
Try this, Use a Relational Operator block where you can specify any data type for the inputs. Specify the output data type as bo...

26 days 前 | 0

| 已接受

已回答
i'm using bus selector block but once i add 4 or more signal, it is showing only one output.
Un-check the "Output as virtual bus" option at the dialog? https://www.mathworks.com/help/simulink/slref/busselector.html

29 days 前 | 0

已回答
How do I change the properties of an Enum stored in a data dictionary programmatically?
Follow this? https://www.mathworks.com/help/simulink/ug/store-data-in-dictionary-programmatically.html

1 month 前 | 0

| 已接受

已回答
Simulink Solver Settings Doubt
You could do experiments to find out why. Use To Workspace block with -1 as sample time to log the inputs. Run simulation with d...

1 month 前 | 0

已回答
error using mex function.
Follow this and make sure you got the correct version. https://www.mathworks.com/matlabcentral/answers/313298-i-already-have-mi...

1 month 前 | 1

已回答
List all the ports of a subsystem and it's data types
This answer should also apply to a Subsystem block. https://www.mathworks.com/matlabcentral/answers/95626-how-do-i-query-the-da...

1 month 前 | 0

加载更多