Trigger ADC event
Select event to trigger ADC sampling
Since R2026a
Model Configuration Pane: Hardware Implementation / Embedded Coder Hardware Support Package / Hardware board settings / Target hardware resources / TSG3
Description
Specifies the event that triggers ADC sampling for the TSG3 module.
Note
The TSG3 trigger is currently limited to ADC groups that are mapped to Scan Group 4.
Dependencies
To enable this parameter, select Configure TSG30 / Configure TSG31parameter.
Settings
None
(default) |
Valley
|
Peak
|
Valley and peak
None: No ADC trigger event will be generated.
Valley: The ADC will be triggered at the valley point of the PWM cycle (typically the minimum point of the carrier waveform).
Peak: The ADC will be triggered at the peak point of the PWM cycle (typically the maximum point of the carrier waveform).
Valley and Peak: The ADC will be triggered at both the valley and peak points of the PWM cycle.
Recommended Settings
No recommendation.
Programmatic Use
| No programmatic use is available. |
Version History
Introduced in R2026a