spoll (visa)
(To be removed) Perform serial poll on VISA objects
This visa object function will be removed in a future release. Use
visadev
object functions instead. For more information, see Version History.
Syntax
out = spoll(obj)
out = spoll(obj,val)
[out] = spoll(obj)
[out,statusByte] = spoll(obj)
[out] = spoll(obj,val)
[out,statusByte] = spoll(obj,val)
Arguments
| A VISA object or an array of VISA objects. |
| A numeric array containing the indices of the objects in
|
| The VISA objects ready for servicing. |
| The service request (SRQ) line status byte. |
Description
out = spoll(obj) performs a serial poll on
the instruments associated with obj. out
contains the VISA objects that are ready for servicing. If no objects are ready for
servicing, then out is empty.
out = spoll(obj,val) performs a serial
poll and waits until the instruments specified by val are ready
for servicing. An error is returned if a value specified in val
does not match an index value in obj.
Using this syntax, spoll blocks access to the MATLAB Command Window until the objects specified by val
are ready for servicing, or a timeout occurs for each object specified by
val. The timeout period is specified by the
Timeout property.
[out] = spoll(obj) returns the object or an array of
objects.
[out,statusByte] = spoll(obj) returns the status byte along
with the object or an array of objects.
[out] = spoll(obj,val) returns the object and the value
specified in the index value of the object.
[out,statusByte] = spoll(obj,val) returns the status byte
along with the object and the value specified in the index value of the
object.
Examples
If obj is a four-element array and val is
set to [1 3], then spoll will block access to
the MATLAB Command Window until the instruments connected to the first and third
VISA objects have both requested servicing, or a timeout occurs.
Example of second output argument:
v1 = visa('keysight', 'TCPIP0::yourdomainname.com::inst0::INSTR');
v2 = visa('keysight', 'TCPIP0::yourdomainname.com::inst01::INSTR');
fopen([v1 v2]);
out1 = spoll(v1);
out2 = spoll([v1 v2], 1);
out3 = spoll([v1 v2], [1 2])
[out4 statusBytes] = spoll([v1 v2])
[out5 statusBytes] = spoll([v1 v2], 2)
fclose([v1 v2]);Tips
Serial polling is a method of obtaining specific information from VISA objects
when they request service. When you perform a serial poll, out
contains the VISA object that have requested servicing.
If obj is an array of VISA objects
Each element of
objmust have the sameBoardIndexproperty value.Each element of
objis polled to determine if the instrument is ready for servicing.
If you specify a second output argument when you call an spoll,
full serial poll bytes are returned in addition to the SRQ line status in the second
argument.
Note
To get a list of options you can use on a function, press the Tab key after entering a function on the MATLAB command line. The list expands, and you can scroll to choose a property or value. For information about using this advanced tab completion feature, see Using Tab Completion for Functions.
Version History
Introduced in R2010aSee Also