na_0004: Simulink model appearance settings
Since R2020a
Guideline Publication
Control Algorithm Modeling Guidelines - Using MATLAB®, Simulink®, and Stateflow®
Sub ID Recommendations
NA-MAAB — No recommendations
JMAAB — a
MATLAB Versions
All
Rule
Sub ID a
Simulink model appearance settings shall conform with the project settings.
Display option
On the Simulink toolstrip, these parameters are available in the Modeling tab, under Environment.
Parameter | Setting |
---|---|
Model Browser | Deselect Model Browser. |
Status Bar | Select Status Bar. |
Toolstrip | Select Toolstrip. |
Zoom | Select Zoom (Normal View 100%). |
On the Simulink toolstrip, these parameters are available in the Debug tab, under Information Overlays.
Parameter | Setting |
---|---|
Library Links | Select Hide All Links. |
Linearization Indicators | Select Linearization Indicators. |
Ref. Model I/O Mismatch | Deselect Ref. Model I/O Mismatch. |
Ref. Model Version | Deselect Ref. Model Version. |
Sample Time Colors | Deselect Colors. |
Execution Order | Deselect Execution Order. |
On the Simulink toolstrip, these parameters are available in the Format tab.
Parameter | Setting |
---|---|
Background color | Select white option from the Background list. |
Foreground color | Select black option from the Foreground list. |
To access the parameter below, On the Simulink toolstrip, open Simulink Coder™ from Apps, select C Code tab and choose Code Interface.
Parameter | Setting |
---|---|
Storage Class Indicator | Deselect Storage Class Indicator. |
On the Simulink toolstrip, these parameters are available in the Debug tab, under Information Overlays.
Parameter | Setting |
---|---|
Base Data Types | Deselect Base Data Types. |
Alias Data Types | Deselect Alias Data Types. |
Signal Dimensions | Deselect Signal Dimensions. |
Testpoint | Select Test Point. |
Logging and Viewer indicators | Select Logging & Viewers. |
Nonscalar Signals | Select Nonscalar Signals. |
Rationale
Sub ID a:
Standard model appearance improves readability.
Verification
Model Advisor check: Check for Simulink diagrams using nonstandard display attributes (Simulink Check)
Last Changed
R2020a
See Also
MISRA AC SLSF 023A
Version History
Introduced in R2020a