Check usage of Discrete-Time Integrator block
Check ID:
mathworks.jmaab_v6.jc_0627
Guideline: jc_0627: Usage of Discrete-Time Integrator blocks
Description
Checks use of the Discrete-Time Integrator block.
For Discrete-Time Integrator blocks, check if:
Block parameter Limit output is selected.
Saturation limits is defined using a
Simulink.Parameter
orMPT.Parameter
object whose data type isauto
.
This check requires a Simulink® Check™ license.
Check Parameterization
This check does not include sub-checks because the MAB modeling guideline provides only one sub ID.
For reference, the MAB guideline sub ID(s) that are recommended for use by the NA-MAAB and JMAAB modeling standards organizations are:
NA-MAAB — a
JMAAB — a
Results and Recommended Actions
Guideline Sub ID | Condition | Recommended Action |
---|---|---|
jc_0627_a: Check Saturation limit settings of Discrete-Time Integrator blocks | Block parameter Limit output is cleared. | Select the Discrete-Time Integrator block parameter Limit output. |
Capabilities and Limitations
Runs on library models.
Supports exclusions.
Analyzes content of library-linked blocks. By default, the input parameter Follow links is set to
on
.Analyzes content in masked subsystems. By default, the input parameter Look under masks is set to
graphical
.