System Id on system with tank

1 次查看(过去 30 天)
Steven
Steven 2013-12-17
编辑: Steven 2013-12-17
I'm trying to model a system with a tank with a fluid that runs through a cooler and heater to run temperature control on it. A temperature sensor in the tank monitors the temperature. I have been able to run the system open loop to collect data for a system identification, I'll pulse the heater and the cooler independently and then fit the data with the system id toolbox. One of the problems is the tank functions like a giant integrator and the system id has trouble with the lower frequency dynamics. Is there any way to get the short term dynamics of the cooler or heater separate from the longer frequency tank dynamics from data that has both?

回答(0 个)

类别

Help CenterFile Exchange 中查找有关 Model Predictive Control Toolbox 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by