Warnings for Non-existent Ports in a Matlab Function Block

2 次查看(过去 30 天)
Hi all
I have a rather large model in Simulink. When it runs, it gives me a number of warnings similar to the following one:
Warning: Block 'SS_SplitSimulink_Model1/MATLAB I1/ SFunction ' output 'Inf'
for element 23 of output port 2 at minor time step 0.00016552
The strange thing is that the "MATLAB I1" block has only one output port. Is there any way in which a Matlab function block can have something like hidden ports? I get 'Inf" and "NaN" warnings, which is obviously quite troubling...
I apologise if I'm not giving enough info.

采纳的回答

Niklas Nylén
Niklas Nylén 2014-4-1
编辑:Niklas Nylén 2014-4-1
If the S-function was generated in Real time workshop/Simulink coder you can right click MATLAB I1 and select Look under mask. You should be able to see another "layer" where more outputs may exist.
  3 个评论
Niklas Nylén
Niklas Nylén 2014-4-1
编辑:Niklas Nylén 2014-4-1
Possibly outport 2 inside the S-function is only used for internal feedback and that is why there is no second outport on 'MATLAB I1'. As far as I know it is not possible to look inside an S-function unless you have access to the source code.
Niel
Niel 2014-4-1
Thank you, Niklas. It sounds good. If you get another idea in time, feel free to share =)

请先登录,再进行评论。

更多回答(0 个)