Dear All,
I am trying to implement a non liner voltage dependent load model. The load models are exponential and as well as polynomial.
For Instance:
Power = P0 (V/Vo)^np
I have trying to implement this as below:
I want to acheive a non linear (distorted sinewave) current draw as shown below to conduct load flow and harmonic studies.
2 个评论
回答(1 个)
Joel Van Sickel
2021-9-22
your absolute value will prevent it from every being truly sinusoidal. The model is outputting exactly the math that you have implemented in Simulink. You need to find a different mathematical representation of your current waveform that does not require a divide by voltage since this is a single phase AC system and voltage will always cross 0.
I think the issue is that you are using a distortion model intended for three phase networks and doing them for a single phase network. If you did this with three phase values you should not have to divide by zero as V is not the instantaneous voltage of any phase, but the overal voltage magnitude of the system.