time aligning two signal at different sample rates

42 次查看(过去 30 天)
Most of the techniques I have discovered to time align two signals requires them to be sampled at the same rate. I am aware of the resample() function on matlab but I have a signal sampled at 60 Hz and the other at 200 Hz and I must of course use a rational fraction. Is there a way around this?

回答(1 个)

Star Strider
Star Strider 2014-8-13
According to the documentation on resample, p and q simply have to be integers, and 60 and 200 meet those requirements. It is probably more reliable to downsample the signal sampled at 200 Hz to 60 Hz sampling.

Community Treasure Hunt