- Find each MATLAB Function block or Stateflow chart
- Right click on the block, choose HDL Code > HDL Block Properties...
- Change any property (e.g. InputPipeline), Apply the change, change it back to the original value, and Apply the reverted value.
Problem with simulink and HDL coder
8 次查看(过去 30 天)
显示 更早的评论
I have updated my simulink to the R2014b version. Now I cannot code a simulink file that was easily converted in version R2014a to VHDL. The answer from the HDL Workflow Advisor is:
Abnormal exit: The Block/HDLImplementation pair: ('eml_lib/MATLAB Function', 'Stateflow') is not registered in the implementation database
Does anyone have a clue?
Thanks in advance
0 个评论
采纳的回答
Tim McBrayer
2014-10-20
It sounds as if the HDL data associated with your Stateflow.MATLAB Function block may have become damaged. I don't know if this will work, but please try it out.
This should have the effect of rewriting the HDL data associated with each potentially affected block, which should correct whatever issue you are having.
1 个评论
samira sorayaasa
2021-7-29
it is not useful is any one can help me with this problem ?
HDLCoder
1
08:25 AM Elapsed: 0.18 sec
The Block/HDLImplementation pair: ('modelsimlib/HDL Cosimulation', 'hdldefaults.ModelSimHDLInstantiation') is not registered in the implementation database.
Component:HDLCoder | Category:HDL error
更多回答(0 个)
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 HDL Coder 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!