28388D SCI_A received data is wrong

1 次查看(过去 30 天)
Hi, I have a problem in 28388D SCI communication.the code picture are as follow,the program is transmit the data what you received. on serial debugging interface. I can't receive what I transmit. So I went to CCS try to find out the reason. It turns out that whatever value the upper machine sends it receives value is 255. I don't why and where the bug is?
Thank for your help! Here are some screenshots

采纳的回答

yeyuan zhu
yeyuan zhu 2021-12-8
The result of the problem was to set the oscillator to 10MHz in the hardware configuration