Simulink Real-Time not connecting to SpeedGoat
7 次查看(过去 30 天)
显示 更早的评论
Hello,
I've connected my development PC and the SpeedGoat PC via Ethernet. By pinging the target PC, I can see that there is communication between the two PCs.
My simplistic model is able to build. However, when I select the "toggle target computer connection" in the upper left hand of the screen , the icon remains in "Disconnected".
I am running MATLAB V2020A on the development PC and the SpeedGoat unit is running R2020b.
0 个评论
回答(1 个)
Diego Kuratli
2022-4-12
The MATLAB version on the development PC and the RTOS version on the Speedgoat target computer must match.
Typically the upgrade process is just a click of a button. However, R2020b was a major update for Simulink Real-Time, and some extra steps are required to migrate the Speedgoat target computer to the new RTOS.
Please check out this short video:
Further information is included in the Speedgoat documentation.
0 个评论
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Target Computer Setup 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!