PX4 SITL with Simulink-Based Plant Model
6 次查看(过去 30 天)
显示 更早的评论
Hello, I'm develeoping a simple observer-based controller and I'm trying to implement it on PX4 stack. I'm developing a SITL scheme with Simulink-Based plant model as shown in Monitor and Tune PX4 Host Target Flight Controller with Simulink-Based Plant Model - MATLAB & Simulink - MathWorks. I developed a simple simulink model to check connetivity between my controller and the plant but there is a problem. I'm able to follow all the steps in the tutorial mentioned above but at the end I get the following error in the Simulink controller model:
action: EXT_INIT Creating Target Handler (XCP on TCP/IP)... Build directory: C:\Users\paolo\OneDrive\Documenti\Tesi_magistrale\SITL\partialInformation_controller_SITL_Simulink_ert_rtw Target name: 127.0.0.1 Target port: 17725 action: EXT_CONNECT Connecting to the target...
External Mode Open Protocol Connect command failed
Caused by:
- Could not connect to target application: XCP TCP/IP error: Connect failed
Component:Simulink | Category:Block diagram error
Unable to connect to the 'PX4 Host Target' target for 'partialInformation_controller_SITL_Simulink'.
I think the problem is on model side beacuse if I run the quadcopter model in the example Monitor and Tune PX4 Host Target Flight Controller with Simulink-Based Plant Model - MATLAB & Simulink - MathWorks my controller seems to connect succesfully with this model. This is my model for test connectivity, I'm trying to publish a simple message HIL_GPS with a dummy altitude:
And this is the controller I have developed:
Someone can help me?
Thanks in advice,
Paolo
1 个评论
Manoj Velmurugan
2022-11-25
Did the host target window launch for you?
Also check if some other application is blocking 17725 port.
采纳的回答
Manoj Velmurugan
2022-11-25
PX4 Host target waits until it receives the HIL_SENSOR message. PX4 Host target has not started running as there is no HIL_SENSOR message in your plant model.
For more information, see the following lines in Firmware\src\modules\simulator\simulator.cpp
#if defined(ENABLE_LOCKSTEP_SCHEDULER)
// We want to prevent the rest of the startup script from running until time
// is initialized by the HIL_SENSOR messages from the simulator.
while (true) {
if (Simulator::getInstance() && Simulator::getInstance()->has_initialized()) {
break;
}
system_usleep(100);
}
#endif