Is the power system frequency measured in Phasor mode or Descre or Congtinuse mode?
1 次查看(过去 30 天)
显示 更早的评论
Is the power system frequency measured in Phasor mode or Descre or Congtinuse mode?
1 个评论
Sabin
2023-1-27
Would be helpful to specify what model are you refering to? Also please give a bit more insights into what are you tryibg to do.
采纳的回答
Joel Van Sickel
2023-2-16
In phasor mode, the power system frequency is specified, not measured. The whole power system will simulate at that frequency and not include effects that would case the frequency to change. In continuous and Discrete mode, you can measure the frequency and the frequency can change over time.