FLIR camera connecting both SpinView and Image acquisition toolbox on Matlab

13 次查看(过去 30 天)
Hi,
I use Matlab to have acquisition of FLIR camera. For example, if the exposure time is locked on SpinView, the line "src.ExposureTime = 3000;" will give error. When I change the exposure time to OFF on spinview, it gave no error.
Though I clear all image objects with delete(imaqfind), the error "Multiple image acquisition objects cannot access the same device simultaneously" appears all the time.
I wonder if SpinView is running in the background even if I closed it. I thought SpinView and Image acquisition toolbox should run separately. Please suggest. Thanks.
  3 个评论
AT_HYZ
AT_HYZ 2023-3-13
Coukd you suggest why 'Multiple image acquisition objects cannot access the same device simultaneously' appears though I delete video objects? Is there other ways I could delete previous video objects?
Walter Roberson
Walter Roberson 2023-3-13
If SpinView is still running, the camera might be detected as being in use.
If SpinView is not still running.. try rebooting the camera.

请先登录,再进行评论。

回答(1 个)

Anurag
Anurag 2023-11-22
Hi AT_HYZ,
I understand that you’re having issue with using your FLIR camera with MATLAB, and that even after clearing all the image objects with “delete(imaqfind)” you’re still getting the same error.
Refer to the following points inaddition to what you did to solve the problem:
  • After deleting image acquisition objects (“delete(imaqfind)”), use “imaqreset” to reset the Image Acquisition Toolbox.
  • Check for other applications accessing the camera through the device list.
  • Verify proper camera connection and availability in MATLAB using “imaqhwinfo”.
  • Update FLIR camera drivers.
Please refer to the following MathWorks documentation link for more information on “Creating Image acquisition objects” and FLIR camera driver:
Hope this helps!