Hello Everyone,
We are facing a delicat situation here. We got a Speedgoat setup that work pretty well curently, that we use to perform HIL test on our ECU.
We are trying to set several fault on ECU, by sending invalid data on various Input thanks to RT Target. However when we want to calculate the detection time (eg : Timestamp when the fault is detected by our ECU - Timestamp when we inject the fault), we need to interrogate the RT Target with the getsignal method, and this method need (after our test) about 50 ms to get the answer, witch is really too long for us ...
Is there any method to perform this kind of test ? Or a way to speed up the getsignal() answer ?
Thank you very much for your help
Regards
0 个评论
采纳的回答
Diego Kuratli
2023-5-8
The getsignal call might not be the right one for your use case. There is some overhead because getsignal has to 1) find the signal, 2) send a command to the real-time system, and 3) get the response back from the real-time system.
In your case, I would rather use an instrument object or log the signal.
2 个评论
Diego Kuratli
2023-5-10
You can create the instrument object, and then call it from a M file. Here you can find an example for an app, but essentially the same code can be reused in a MATLAB script: