How do you temporarily disable Fast Restart in Reinforcement Learning.

6 次查看(过去 30 天)
Hello,
I want to temporaly disable fast restart. I wish to monitor actions of the RL environment, but I think the simulation is fast for display and scope. Afterward, I can then retore fast restart for the actual training.
Thank you for the help.

采纳的回答

Deep
Deep 2023-6-22
编辑:Deep 2023-6-23
Here's how you can disable fast restart:
set_param('modelname', 'FastRestart', 'off');
Here, replace 'modelname' with the actual name of your Simulink model.
Please refer to this documentation for more details:

更多回答(0 个)

类别

Help CenterFile Exchange 中查找有关 Sequence and Numeric Feature Data Workflows 的更多信息

产品


版本

R2023a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by