My motivation is to use the constant impedance load and the constant current load within the Simscape Electrical model when I only know the active power (rms), reactive power(
17 次查看(过去 30 天)
显示 更早的评论
I would like to understand how to model the single-phase constant impedance load in the Simscape Electrical? when I only know the active power (rms), reactive power(rms) & the rated voltage (rms) of the load. I would like to understand how to model the single-phase constant current load in the Simscape Electrical?
With the Simscape Electrical constant current model. Can I directly use the formula for calculating the consumed current when I know the power and the nominal voltage (rms)?
0 个评论
回答(1 个)
Ayush Aniket
2023-8-16
编辑:Ayush Aniket
2023-8-16
To model a constant impedance load you can use the active power (P), reactive power (Q) and the rated voltage (V) information. From these values, you can calculate the impedance magnitude (|Z|) and angle (θ) using the following formulas:
Once you have the impedance magnitude and angle, you can set them in the "Impedance" block to model the constant impedance load.
To model a constant current load, you need to know the consumed current (I) and the nominal voltage (V). You can directly use the formula I = P / V, where P is the active power, to calculate the consumed current. Then, you can set this current value in the "Current Source" block to model the constant current load.
You can also input these formulas in the respective blocks given you have defined the known powers and voltage information in the base MATLAB workspace and use those variables.
Hope this helps!
0 个评论