xcp on serial Custom board c2000

95 次查看(过去 30 天)
I connected my custom c2000 320f28335 mcu board via sci_a with com port to simulink for xcp debugging, but there is time out error on connection.
Is there any specific hardware configuration?
matlab version 2022b.
the error is :
Could not connect to target application: XCP internal error: timeout expired, in response to XCP CONNECT command
  1 个评论
ali
ali 2023-8-23
Sci-a connected to pc via USB to TTL device, on com port and I configured this port number in hardware configuration in simiulink and also I checked pin number of sci-a

请先登录,再进行评论。

采纳的回答

ali
ali 2023-8-26
in my case the problem was due to Gnd connection of board and USB to TTL device, I had not connected Gnd,
after I connect it, external mode works correctly

更多回答(0 个)

产品


版本

R2022b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by