Couplers in RF Blockset

6 次查看(过去 30 天)
Nikolay Tulumdzhiyan
回答: Shubham 2024-10-7
What means return loss in Coupler block in RF Blockset? In Help write "Loss of signal power due to impedance mismatch of the Directional coupler" - what impedance tell about? I think, it cant be external load. May be there tell about mismatch output and input impedance in Coupler

回答(1 个)

Shubham
Shubham 2024-10-7
Hi Nikolay,
In the RF Blockset's "Coupler" block, the "Return loss" parameter refers to the signal power lost due to impedance mismatch between the coupler and the connected system. This mismatch is typically evaluated against a reference impedance of 50 ohms.
  • Reference Impedance: The coupler's reference impedance can be set as a scalar or a positive three-tuple vector, with a default of 50 ohms. If the reference impedances of all ports differ, the model normalizes them to 50 ohms.
  • Return Loss: This indicates the amount of signal reflected back to the source due to impedance mismatch. An infinite return loss indicates perfect impedance matching with no reflection, while a finite return loss suggests some reflection and an impedance mismatch. Higher return loss values indicate better matching and less signal reflection.
For more details, please refer to the MathWorks documentation on the "Coupler" block:
Hope this helps.

类别

Help CenterFile Exchange 中查找有关 S-Parameters and Linear Components 的更多信息

产品


版本

R2023a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!