FACING THE ISSUES MENTIONED BELOW I DON'T KNOW WHAT TO DO NOW WHAT EVER I DO, THERE IS NO BETTERMENT HAPPENING IN THE SIMULATION OF THE BATTERY MODEL OF A BATTERY PACK. KINDLY SOMEONE HELP ME IN THIS ITS URGENT.
'Output Port 1' of 'batteryModel2november/Constant' is not connected.
Ungroup 6 similar
Component:Simulink | Category:Block warning
'Output Port 1' of 'batteryModel2november/Signal Builder' is not connected.
Component:Simulink | Category:Block warning
'Output Port 2' of 'batteryModel2november/Signal Builder' is not connected.
Component:Simulink | Category:Block warning
'Output Port 3' of 'batteryModel2november/Signal Builder' is not connected.
Component:Simulink | Category:Block warning
'Output Port 4' of 'batteryModel2november/Signal Builder' is not connected.
Component:Simulink | Category:Block warning
'Output Port 1' of 'batteryModel2november/Signal Builder1' is not connected.
Component:Simulink | Category:Block warning
First solve for initial conditions failed to converge. Trying again with all high priorities relaxed to low.
Component:Simulink | Category:Model warning
Unable to satisfy all initial conditions. The variables involved are listed below. The following variables are involved in a constraint that conflicts with their targets: 'Subsystem20.Cell1.cell_temperature' (Temperature) Here are the equations involved: all components involved'batteryModel2november/Subsystem20''batteryModel2november/Subsystem20/Cell1'Equation location is: 'C:\Program Files\MATLAB\R2023a\toolbox\physmod\battery\shared_library\m\+batteryecm\table_battery.sscp' (no line number info) 'batteryModel2november/Subsystem20/T_amb1'Equation location is: 'C:\Program Files\MATLAB\R2023a\toolbox\physmod\simscape\library\m\+foundation\+signal\+sources\constant.ssc' (line 21) 'batteryModel2november/Subsystem20/convection1''batteryModel2november/Subsystem20/convection1/constant T'Equation locations are: 'C:\Program Files\MATLAB\R2023a\toolbox\physmod\simscape\library\m\+foundation\+thermal\+sources\controlled_temperature.ssc' (line 33) 'C:\Program Files\MATLAB\R2023a\toolbox\physmod\simscape\library\m\+foundation\+thermal\+sources\controlled_temperature.ssc' (line 34)
Component:Simulink | Category:Model warning
An error occurred while running the simulation and the simulation was terminated
Caused by:
- ['batteryModel2november/Solver Configuration']: At time 1696.547995, one or more assertions are triggered. See causes for specific information.
- Temperature adjusted first time constant must be greater than zero. The assertion comes from: Block path: batteryModel2november/Subsystem20/C150Assert location: o (location information is protected)
Component:Simulink | Category:Block error