I have a "hrv" signal which has variable sampling frequency. How can I sampling this signal in 4Hz(250ms) without using "interp1" function, only use linear interpolation. My hrv is like that: [ 600 720 780 750 610 640 710 750 690 620 640 700 745 710 670 ].
Have a nice day
  1 个评论
Star Strider
Star Strider 2015-4-27
Are your data R-R intervals? (I suspect they are.)
I don’t understand that you would want to interpolate them. Just use the R-R intervals (likely in milliseconds) that you have and analyse those. (I might add that you need considerably more than you posted for adequate determination of HRV. Ideally, you need at least 24 hours of data.)

请先登录,再进行评论。

回答(2 个)

gntrdm
gntrdm 2015-4-27
Any idea?

Youssef  Khmou
Youssef Khmou 2015-4-27
编辑:Youssef Khmou 2015-4-27
An alternative solution exists using resample(x,p,q) function where the new signal is sampled with p/q times the original sampling frequency, p and q must be integers, here is an example :
y=sin(2*pi*1.5*(0:0.1:10));
y is R^[1x101] with fs=10 Hz, if we want five times the original sampling frequency, say 50Hz :
z=resample(y,10,2);