MCC USB-231 compatibility with Simulink
4 次查看(过去 30 天)
显示 更早的评论
Hello, I am trying to use the data acquisition toolbox to use my USB-231 DAQ inside of my Simulink model. The DAQ shows up inside of MATLAB and I am able to read and write, but inside of Simulink I am unable to access the board from the Data acquisition toolbox's Analog Input/Output. Is there any troubleshooting I can do to get my board to show up or is there some other workaround I need to get it to work in Simulink. Thank you for any help you can give me.
0 个评论
采纳的回答
Walter Roberson
2024-6-28
The USB-231 is not a supported device. The supported devices are listed at
Perhaps it "works" as an unsupported device.
However,
Note: The support package does not support counter/timer subsystems, digital I/O subsystems,
triggered acquisition, specialized voltage measurements (thermocouple, etc.),
or the use of Simulink data acquisition blocks for Measurement Computing DAQ hardware.
3 个评论
Walter Roberson
2024-6-28
All Measurement Computing devices cannot use the analog input/output blocks.
I would suggest using a MATLAB Function Block in a discrete model . However, I do not know whether it would be possible to use Acceleration mode with such an arrangement.
更多回答(0 个)
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Data Acquisition Toolbox 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!