How to make static variable in Simulink
21 次查看(过去 30 天)
显示 更早的评论
I have several identical simulink models, where only the parameters vary:
Simulink block 1 uses the variables x.a{1}, x.b{1}, x.c{1} etc.
Simulink block 2 uses the variables x.1{2}, x.b{2}, x.c{2} etc
... up to Simulink block n using x.a{n} etc. The constants are used in gains, sums state space models etc.
How can i avoid hard coding the above numbers 1 through n in each and every block? I.e. i want Simulink block 1 to only contain the number 1 one time.
Hope this makes sense :)
Benjamin
0 个评论
采纳的回答
Sebastian
2011-2-28
You could use a masked subsystem and just have the block instance number n as a parameter. Then in the mask initialization function you can access the structure fields and map to some local variables.
3 个评论
Paulo Silva
2011-2-28
Unless a variable is defined in a mask that variable will be the same one that's on your workspace, when your start the simulation simulink gets the values for each variable (for example one Constant block with the variable MyVar in the Value).