how to find differences in two simulink configuration settings using m-script
9 次查看(过去 30 天)
显示 更早的评论
Hello,
I am comparing two simulink configuration settings using visdiff command. here is my code:
Simulink.BlockDiagram.saveActiveConfigSet(bdroot, 'active_config')
visdiff('active_config', 'standard_config')
when I type visdiff, its giving comparision report.
But what I need is, If I find any difference between config then I should say different configuation is active else its fine. This should be done using m-script.
3 个评论
Jakob Janecek
2015-5-20
Thank you for clarifying the issue. Unfortunately there is no API available that makes this possible at the moment. The only way to view differences is, as you have already identified, to run visdiff which generates a comparison report.
采纳的回答
Nobel Mondal
2015-5-21
You can return a variable if you run the function 'active_config' after you have saved it as mentioned in the question.
>> cs = active_config();
If you create two such variables for two different models, then 'isequal' is directly going to tell you if they have the exact same configurations.
Finding the exact parameters for differentiation might require to write your own api. The list of properties in a config set is already available in the same active_config.m file. Maybe, you could pass each (or only the ones you're interested into) property value one-by-one and compare. (Bit of a brutal check)
7 个评论
Nobel Mondal
2015-5-22
You could put them in the paramList - all the parameters which you want to check for - in that cell array.
>> paramList = { 'SolverType'; 'SaveOutput', ...
'SystemTargetFile', 'ProdHWDeviceType', ... 'and_anything_else_you_want_to_check_for'};
更多回答(0 个)