Can fast restart be set programmatically?
3 次查看(过去 30 天)
显示 更早的评论
My model takes a long time to initialize and compile relative to simulation run time. This model is called iteratively in a script using sim(). I hoped to use the Fast Restart feature but the R2015a documentation indicates that Fast Restart can only be used interactively. I verified that my model can use Fast Restart when simulated interactively by clicking the run button. Is there really no way to avoid recompilation programmatically?
0 个评论
采纳的回答
Sebastian Castro
2015-8-17
编辑:Sebastian Castro
2018-4-25
Unfortunately, Fast Restart can't be used programmatically in its initial R2015a release.
In R2015b and later, you can enter:
set_param(modelName, 'FastRestart', 'on')
- Sebastian
0 个评论
更多回答(1 个)
另请参阅
产品
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!