Error in port widths or dimensions

2 次查看(过去 30 天)
Hi everyone, I have a problem when running my simulink file. I have pid block and s-function block diagram in simulink file with the 11 outputs and 1 input. When I try to run this file I receive the following error for pid block:
Error in port widths or dimensions. Output port 1 of 'project1_simu/PID Controller' is a one dimensional vector with 11 elements
and the following error for s-function file:
Error in port widths or dimensions. Input port 1 of 'project1_simu/S-Function' is a one dimensional vector with 1 elements
How to solve this error?

采纳的回答

Kaustubha Govind
Kaustubha Govind 2012-2-1
Apparently the S-function expects a scalar value, but you are feeding in a vector of length=11. If you've written the S-function, you need to use something like "ssSetInputPortWidth(S, 0, 11);" or "ssSetInputPortWidth(S, 0, DYNAMICALLY_SIZED);" in mdlInitializeSizes.
  2 个评论
yana osman
yana osman 2012-2-13
Thanks...but i received another error
" State derivatives returned by S-function 'chiu_sfcn' in 'project1_simu/S-Function1' during flag=1 call must be a real vector of length 11."
Do you have any ideas on how to solve this?
Kaustubha Govind
Kaustubha Govind 2012-2-13
The error clearly states the issue. The value you are returning for flag=1 needs to be a real vector of length=11. What are you returning in "sys"?

请先登录,再进行评论。

更多回答(0 个)

类别

Help CenterFile Exchange 中查找有关 Block and Blockset Authoring 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by