How do I run a simulink model in real-time in normal mode

11 次查看(过去 30 天)
I can't seem to figure out how to run a simulink model in real-time in 'Normal' mode
The Mathworks guides says "In your Real-Time Windows Target model, set values for the Sample Time and Maximum Missed Ticks block parameters to prevent missed ticks."
but how to you find this 'Real-Time Windows Target model' that should contain 'Sample Time' and 'Maximum Missed Ticks'.
My models works well in 'External' but as soon as I change to 'Normal' mode it runs in nun real time.
Is there suppose to be a sync block or other blocks that need to be added in my model
I have spent hours on this please help me anybody?
Thanks Behel

回答(3 个)

Titus Edelhofer
Titus Edelhofer 2012-3-14
Hi Behel,
not sure, if I fully understand: Real-Time Windows Target is a compiled Simulink model. The model runs in real-time and Simulink (in External mode) is "only" used to control the real-time application. When you change to "Normal mode", Simulink is again in charge and Simulink always executes simulations as fast as possible (usually therefore faster than real-time ;-)). If you want to run Simulink models in Simulink in "soft" real-time, there are methods to slow down the simulation (typically by using an S-function that compares the system time with the simulation time, and waits in between). Many examples are on the file exchange, see e.g. this one.
Titus

bethel o
bethel o 2012-3-14
编辑:John Kelly 2013-11-13
Thank you Titus for your reply

Doug Eastman
Doug Eastman 2012-3-14
Running in real-time in normal mode is a new feature of Real-Time Windows Target in R2012a. To run in real-time you do need to add the Real-Time Synchronization block. The rtvdp model shows an example of using this block.
  2 个评论
bethel o
bethel o 2012-3-14
Thanks Doug,
Ok this clears up a lot of things because I was using R2011a. Its crazy how one gets left behind by technology in no time.
I guess I have wasted my time for nothing because I cannot even properly work in the 'External' mode because the 'make' process of the 'build' keeps giving an error regarding the sfunction for my external device. I officially hate computers SMASH SMASH
Jan Houska
Jan Houska 2013-11-14
If you update to R2012a or later, you will not need to compile your model to run it in Normal Mode. Hence there will be no compiler error for the S-function and everything should just work.