Simscape Full-Bridge Error

2 次查看(过去 30 天)
Ryan
Ryan 2017-6-30
I'm using a PWM generator as the gate signal for the full-bridge block. I want to simulate a single phase full-bridge inverter. I'm getting an error that says since the pwm generator has an 8 pulse output and the converter block is only 4 pulses, it won't work.
Can someone tell me what I'm doing wrong and how to simulate a single-phase full-bridge inverter with this block? (The example is no help)
I've attached a few illustrative pics. Thanks!
<<
>>

回答(1 个)

Joel Van Sickel
Joel Van Sickel 2020-9-2
Hello Ryan,
you are using a PWM generator designed for a 3 level inverter. This is a 2 level full-bridge. Please use the 2 level PWM generator, and select the appropriate topology (it will default to a 6 device inverter, but can be set to work for a full-bridge).
Regards,
Joel

类别

Help CenterFile Exchange 中查找有关 Switches and Breakers 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!