can someone help me with a model of how to use the external control of PQ in 3 phase dynamic load?
6 次查看(过去 30 天)
显示 更早的评论
I need to design a controller by using external control of PQ in a 3 phase dynamic load.I am using a 2-area kundur system.What i need to basically do is if the difference between the mechanical rotor angle (theta) is greater than or equal to a particular value,then i need to add 10% of the current load in one area and subtract 10% in another area. can i get any idea of how i can do it
1 个评论
Abhi Sundararaman
2017-10-12
You could just measure the value of the rotor angle, compare it with a constant block (you could just subtract the two and use the comparetozero block), and then if the output is true, add/subtract 10% where necessary.
The conditional part of this could be done with an enabled subsystem, where the output of the comparison (rotor angle >= particular value) enters the enable port of the enabled subsystem. Make it such that the enabled subsystem outputs 10% of the current load and subtract/add this signal to the corresponding area. Since the enabled subsystem is connected to the rotor condition will only output 10%*currentload if the rotor condition is true.
Above is a simplified version of what you could use. You take the difference in rotor angle and compare it to a value. Then you check your condition (change in rotor angle > value), if this is true then the enabled subsystem will run and take 10% of the current load. The outport1 would feed back to your model and be subtracted/added from/to the current load.
回答(0 个)
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Schedule Model Components 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!