i am designing simulink model with xilinx blocksets and simulink block sets when i tried to generate hdl code it is showing error Data-type 'Bool' is unsupported for HDL code generation
Gateway in is configured for boolean data type
  1 个评论
Walter Roberson
Walter Roberson 2012-6-11
http://www.mathworks.com/matlabcentral/answers/29922-why-your-question-is-not-urgent-or-an-emergency

请先登录,再进行评论。

回答(2 个)

Yongfeng
Yongfeng 2012-6-11
Bool is not a Simulink data type and HDL Coder is not able to generate code for it. That is what the error says.
Please check your model to find how Bool propagates from Xilinx scope (between gateway-in and gate-way out) to Simulink blocks and try to avoid it. Alternatively, you can convert it to fixed-point data type, such as (U)Fix_1_0. HTH

Kaustubha Govind
Kaustubha Govind 2012-6-11
Seems like this might be a Xilinx System Generator limitation. It might be best if you try contacting Xilinx Support, because not a lot of people on this forum have experience with System Generator.